Description
Description
Standards
- 
                                            ProductIEC 60502; NF C32-207/A1
Application
A05VV-U/R cables are designed for households. They can only be used for heating and cooking appliances if there is no risk of radiations or contact with hot parts.
Installation and design
Installation
Open air.
Sheath colour
Black. Others under request
Characteristics
Characteristics
Construction characteristics
Construction characteristics
                                                                Sheath colour
                                                            
                                                            
                                                                Black 
                                                            
                                                        
                                                                Conductor flexibility
                                                            
                                                            
                                                                Solid class 1 
                                                            
                                                        
                                                                Conductor material
                                                            
                                                            
                                                                Bare copper 
                                                            
                                                        
                                                                Insulation
                                                            
                                                            
                                                                PVC 
                                                            
                                                        
                                                                Outer sheath
                                                            
                                                            
                                                                PVC 
                                                            
                                                        Dimensional characteristics
Dimensional characteristics
                                                                Conductor cross-section
                                                            
                                                            
                                                                2.5 mm²
                                                            
                                                        
                                                                Number of cores
                                                            
                                                            
                                                                3 
                                                            
                                                        
                                                                Approximate weight
                                                            
                                                            
                                                                214 kg/km
                                                            
                                                        
                                                                Maximum outer diameter
                                                            
                                                            
                                                                12.5 mm
                                                            
                                                        Electrical characteristics
Electrical characteristics
                                                                Rated Voltage Uo/U (Um)
                                                            
                                                            
                                                                300/500 V 
                                                            
                                                        
                                                                Permissible current rating in open air
                                                            
                                                            
                                                                26 A
                                                            
                                                        
                                                                Voltage drop, single phase
                                                            
                                                            
                                                                14.0 V/A.km
                                                            
                                                        Mechanical characteristics
Mechanical characteristics
                                                                Mechanical resistance to impacts
                                                            
                                                            
                                                                Low 
                                                            
                                                        
                                                                Cable flexibility
                                                            
                                                            
                                                                Rigid 
                                                            
                                                        Usage characteristics
Usage characteristics
                                                                Length
                                                            
                                                            
                                                                1000 m
                                                            
                                                        
                                                                Packaging
                                                            
                                                            
                                                                Drum 
                                                            
                                                        
                                                                Flame retardant
                                                            
                                                            
                                                                C2, NF C 32-070 
                                                            
                                                        
                                                                Weather resistance
                                                            
                                                            
                                                                Good 
                                                            
                                                        
                                                                Max. conductor temperature in service
                                                            
                                                            
                                                                70 °C
                                                            
                                                        
                                                                Chemical resistance
                                                            
                                                            
                                                                Accidental 
                                                            
                                                        
                                                                Operating temperature, range
                                                            
                                                            
                                                                -5 ... 60 °C
                                                            
                                                        
                                                                Short-circuit max. conductor temperature
                                                            
                                                            
                                                                150 °C
                                                            
                                                        
                                                                Water proof
                                                            
                                                            
                                                                Accidental 
                                                            
                                                        
                                                                Bending factor when laying
                                                            
                                                            
                                                                3 (xD)
                                                            
                                                        Resources
Resources
Documentation
                                                    Homologation certificate (pdf)
                                                    pdf — 213.1 kB
                                                
                                                
                                            
                                                    H05VV-F datasheet